Vantage 8pg amended jan 2011 latest.indd

Vantage PlusThe best just gets better Natural LED illuminationand Slimline Polymer battery NEW Vantage Digital Ophthalmoscope Digital imaging in your office, operating room, or anywhere you want it As the world leader in binocular indirect
The intuitive and powerful Keeler Software technology we lead the way again with the
allows you to use your PC to provide still or first digital binocular indirect system. Not old
dynamic images, which aid in the analog video but true digital imaging.
documentation and diagnosis of your patient.
Utilize Vantage Digital Wireless in your Increase your practice profile by educating office, operating room, and teaching your patients and their family with digital facility or anywhere you want to capture dynamic imaging in your office.
digital images.
Actual images Technical Specifications Interface
Windows 7 and Windows XP on a PC Taken from USB 2 interface Resolution To test pattern 6 of group 2 on the 1951
Controls
All controls and features of the Vantage Plus USAF TEST PATTERN (conforms to MIL-STD have been maintained 150A standard), when used in combination When installed will work with any video Plugs into PC to record examinations in Vertical
The vertical adjustment is achieved by rotating package capable of receiving video input adjustment the adjustment screw on the mirror holder.
digital format.
from a USB source The image should be adjusted such that the light patch is in the centre To connect camera to PC, Keeler recommends a 5m long USB 2.0A to a mini 5 pin (sometimes Horizontal Factory set
For easy still or dynamic imaging, storage and packaged as USB 2.0A to a mini B lead) adjustment
documentation. Compatible with Windows 7 and Windows XP.
The camera image can be adjusted ±7 degrees Slimline Wireless The Vantage Plus Digital is approx. 50mm Built on the number one selling LED and The resolution value given above will be longer than the standard Vantage Plus wireless slimline system.
maintained at 350mm to 650mm distance from instrument to the eye under examination The total weight of the complete Vantage Plus Digital is 662g (Vantage Plus is 596g) IncludesVantage Digital Wireless Ophthalmoscope, Note: The distance and range will vary with differing refractive errors of the user. To maximise performance of this product, the Docking Station and power supply, additional user should use refractive error correction aids and adopt a working distance of around 450mm (front of instrument to eye Slimline Polymer battery, Keeler Software, Digital under test) when used with a 20D lens. Wireless Remote Control and Carrying Case.
NEW Vantage Plus LED ConvertibleBright white illumination for a superior retinal view We are delighted to present the new,
exclusive Vantage Plus LED Convertible.
Longest life, brightest and whitest, better detail When you purchase the Vantage Plus LED
you will automatically receive a Xenon
Bulb so you can decide which illumination
25% brighter than standard bulbs you prefer without any extra cost!
The natural LED cooler colour provides New Slimline Lithium Polymer battery weighs brighter, whiter illumination, longer battery life, freedom from purchasing bulbs and a life expectancy of up to 10,000 hours.
Combined natural LED and Lithium Polymer batterycan provide up to 6 hours of use on a single charge "The cooler colour temperature of the natural LED light source Vantage Plus LED resulted in a level of image Clinically, the superior optics combined clarity that I've not found in with the natural LED illumination could Our new Slimline provide greater detail, allowing you to Lithium Polymer battery find retinal pathology that was not visible is as light and as small as New Slimline Lithium Polymer Todd J. Purkiss, M.D., Ph.D., Chief Resident, with the Xenon bulb BIO's. the new mini iPod.
battery (paper clip shows scale) Ophthalmology & Visual Sciences, University of Louisville Unique - Intelligent Optical System (IOS) Exclusive - IOS Optics allows Small Pupil Imaging without any obstructions At last - now when you change the aperture the optics and mirrors automatically adjust
for you, without the need to flip another lever!
Keeler has designed this unique one step movement to make your examinations easier and faster. The (IOS) mechanism (patent pending) means that when you select the small, medium or large aperture the optics automatically adjust, providing 3 dimensional stereoscopic views of the retina through all pupil sizes.
View through Vantage Plus with IOS Optics.
View through NON IOS Optical Systems.
Large Pupil
When looking through a large
When small pupil is selected there is no When small pupil is selected there is an fully dilated pupil the optics obstruction of the retina.
obstruction, reducing your clinical information.
are separated and the light source remains in the upper position, achieving maximum Quality and efficiency The redesigned optics combined with the new natural LED or Xenon light source offer The viewing optics and light brighter high definition retinal images - sources are in a ‘mid position' for maximum stereopsis.
PLUS you get more life from whichever Keeler battery (Metal Hydride or Lithium) Small Pupil
When looking through a small pupil the viewing optics and light source are converged to allow you to view the retina through the smallest pupils The Vantage Plus uses advanced textured engineering materials, providing a lighter, smaller and more compact instrument A new soft cushioned headband has been without compromising the renowned designed to maximise comfort, it adjusts Keeler reputation for robustness, reliability and balances perfectly to suit all head shapes The new teaching mirror just Unique - The new HiMag™ (patented) slides on and off with ease lens just slides on and off with ease The new teaching mirror just slides on and off This unique feature is only offered with with ease allowing two observers to view the the Vantage Plus indirect. It gives you a retina at the same time.
1.6X additional magnification than with a condensing lens alone, providing superb stereoscopic images.
Scratch resistant coated optics New high contrast optics guarantee high quality images The new compact and high contrast at all times and HiMag™ can be viewing optics use natural LED or simply flipped out of view Xenon illumination that gives you when not required.
brilliantly crisp, glare free, superior views of the retina every time.
Filters and Apertures IR/UV filters are built into the optics of the Vantage Plus with optional filters and a choice of 3 apertures plus a soft light diffuser.
View when using a 20D lens Transport your instrument in P D Range: 48 - 76mm
style and choose if you want to use your wheels or carry it on your shoulder.
View when using a 20D lens and the Keeler HiMag™ lens "Overall it is the best binocular indirect ophthalmoscope I have ever used" Mr J McAllister FRCS, FRCOph, Consultant Ophthalmic Surgeon, Windsor Power Supply Options New Slimline Wireless Charger The new wall mountable charger remains as durable as the Standard Wireless battery Keeler wireless technology allows you to move from
charger with the facility to room to room without any constraints. The chargers are
store your extra battery in either desktop or wall mountable, and store an extra
New Slimline Lithium Polymer Battery the top compartment.
lithium battery as a back up, should you need it.
The charger has an easy release button to Never run out of power remove your extra Keeler wireless system comes standard with two lithium batteries (slimline) and they last so long, it may take New Slimline Wireless Charger months before you need to charge them again.
Standard Lithium Battery New Slimline Lithium The New Slimline Lithium Polymer battery Our original lithium battery lasts can give you up to 6 hours of use, weighs only up to 11 hours of use and fits 53 grams, and is nearly 70% lighter than the neatly into the charging unit.
Standard Wireless Charger standard battery. It is also much smaller and can fit nicely into the palm of your hand.
"I used the Plus almost daily for four months before I had to recharge the battery" Todd J. Purkiss, M.D., Ph.D., Chief Resident, Ophthalmology & Visual Sciences, New Slimline Lithium Polymer Battery Standard Lithium Battery University of Louisville Power Supply OptionsWired SmartPack is a stylish power Alternatively, if your power supply needs to be stationary you can purchase the WallPack supply system that combines which fits neatly on the wall. Your indirect can be mounted on the bracket it comes with.
3 options in one product.
Which system is right for you? No longer will you need to purchase a portable system for domiciliary use, another Vantage Plus Usable Life system for mounting on your wall and another for tabletop use.
* This measurement is based upon the illumination being used at normal examination power Keeler Ltd.
Keeler Instruments Inc.
Clewer Hill Road, Windsor 25 Deerdykes View, 456 Parkway, Broomall Berkshire, SL4 4AA Tel: +44 (0) 1753 857177
Tel: 1 610 353 4350
Fax: +44 (0) 1753 827145
Fax: 1 610 353 7814
Tel: +44 (0) 1236 721214
Fax: +44 (0) 1236 721231

Source: http://www.ophthalmic.com.my/product/pdf/Vantage_Plus_2011.pdf

colegioveterinario.cl

Rev. Inst. Med. Trop. Sao Paulo53(1):39-44, January-February, 2011doi: 10.1590/S0036-46652011000100007 ANTEMORTEM DIAGNOSIS OF HUMAN RABIES IN A VETERINARIAN INFECTED WHEN HANDLING A HERBIVORE IN MINAS GERAIS, BRAZIL Mariana Gontijo de BRITO(1), Talita Leal CHAMONE(1), Fernando José da SILVA(2), Marcelo Yohito WADA(3), Alexandre Braga de MIRANDA(4),

Microsoft word - xulanexus_schinetsky.docx

Volume 13, Issue 1, December 2015 . Research Manuscript. 1-8. Effects of Medications on Pupillometry Measurements of Sedation in the Intensive Care Unit! Johlee Schinetsky, Jeffrey Quach, Ashlynn Volpe, Natalie Tran and Samantha Gaffney Faculty Mentor: Dr. Jessica Johnson, Pharmacy Abstract Administration of sedatives and opioid analgesics to hospitalized patients in the Intensive Care Unit (ICU) is a common event as part of the usual process of care. Accidental over-sedation leads to increased patient harm, prolonged ICU length of stay, and